top of page

Greenhouse Electric Roll Up Motor, 44 nM Moteur électrique enroulable

C$198.00Price

Use with a roll up wall 100' or less.


Excellent reliability. Ideal for ventilation, light deprivation and blackout systems.


24 volt DC motor, comes with built in limit switches. Torque: 44 Nm - RPM: 4.5 - Amps: 2 (max: 4) - Revolutions: 40 - Weight: 3.5 Kg



Installation:


Roll up motors to incremental controller (thermostat model)



1) Install the telescopic tubes.  The arm is installed on the gable wall baseboard, typically 1.5 meters from the roll up tube.  Check the tube extension to ensure that there is sufficient length to reach the top of the roll up wall.  Lubricate (white grease, not supplied).



2) Connect the telescopic tube to the motor.



3) Attach the roll up tube to the output coupler, but do not bolt them together until the limit switches are adjusted (see the hint below).



4) Wire (cabtyre two wire cable, not supplied) the motors to the box (the motor outputs are in pairs on the box).  Make temporary connections until you are sure the motor is winding in the correct direction.    Position the box to avoid excessive lengths of power cable (from the box to the motors) to minimize voltage drop to the motors.



5) SETTING THE LIMIT SWITCHES


With the roll up wall at grade set the limit switch (each increment is a rotation of the motor), remove the cap, push the dial in and turn.


Setting the green dial at 1 and the red at 24 will move the wall up (and down) 23 revolutions.  The dial closest to the ground determines the lower stop.



Hints:


With the roll up tube at grade, disconnect the roll up tube, let the motor travel to the limits of the bottom stop, then reconnect the roll up tube.



If the motor travel is opposite to what is desired then switch the wire connections to the motor.



Rapid changes in the direction of the motors (like when setting limits) can cause the fuses to blow.  3.5 amp fuse max.



6) Connect the thermostat to the box.  The thermostat should be wired to make contact on a temperature rise (cooling).   Typically with the wall down have the thermostat set to its maximum range.  Locate the thermostat away from the wall and away from any fans to avoid rapid temperature fluctuations.



7) The boxes are pre-set at 15 minute of off-time, and 15 seconds of on-time; these settings can be adjusted.(instructions below)



8) Heat wrap all electrical connections.



Motor Warranty:


We will provide a (reconditioned or new) replacement motor for any motors that fail within 18 months of purchase if:


- they are installed with a Steele GC Inc.controller (3.5 amp max. fuses)


- the motors do not sit in standing water;


- the limit switch caps are closed,


- the wall is covered with single poly only,


- the motor is installed in the manner specified above,


- the equipment is not modified.



                                                         Steele GC Inc™









ADJUSTING THE INCREMENTAL OPENINGS




There are 2 sets of white and blue dials, on a relay, inside the control box.



The top set controls the on time (t on) for the motors, the bottom set controls the off time (t off).



Each white dial has the following increments:



.1 - 1 second


1 - 10 seconds


6 - 60 seconds


1 - 10 minutes


6 - 60 minutes


1 - 10 hours


10 - 100 hours



This is the coarse adjustment.



The blue dial runs from 1 to 10 (10% to 100%) and is the fine adjustment, it selects the percentage of the coarse adjustment time period, that the motors will run.



For a run time of 15 seconds (this is the factory setting), every 10 minutes:


upper dials (on time): white  6-60 seconds, blue dial 2.5


lower dials (off time): white 1-10 minutes;  blue 10



For a run time of 30 seconds, every 20 minutes


upper dials (on time): white  6-60 seconds, blue dial 5.0


lower dials (off time): white 6-60 minutes;  blue 3.3



Roughly speaking it takes 15 seconds to roll up 6” of wall.  Fifteen minutes later (off - time), the motor will energize again; if the temperature remains above the thermostat set point, the wall goes up; if the temperature has dropped the wall goes down.  We suggest that these settings will provide a relatively stable temperature regime.  Various greenhouses and conditions may require either more or less aggressive venting strategies.



                                                        Steele GC Inc™


Both couplers are used with 1-3/8" outside diameter tube.


Various install kits and controllers, sold seperately.


*A netwon metre is a unit of torque in the metric system. 44nM = 32.453 ft-lb.



À utiliser avec un mur enroulable de 30 m ou moins.


Excellente fiabilité. Idéal pour les systèmes de ventilation, d'occultation de la lumière et d'occultation.


Moteur 24 V CC, équipé de fins de course intégrés. Couple : 44 Nm - Vitesse : 4,5 tr/min - Ampères : 2 (max. : 4) - Tours : 40 - Poids : 3,5 kg


Les deux coupleurs sont compatibles avec un tube de 3,5 cm de diamètre extérieur.


Divers kits d'installation et contrôleurs sont vendus séparément.


*Un mètre net est une unité de couple dans le système métrique. 44 nM = 32,453 pi-lb

Quantity
    No Reviews YetShare your thoughts. Be the first to leave a review.
    bottom of page